Safe use of electricity in shrimp farming.

• April 19, 2014 21:20

In industrial shrimp farming, the use of electricity for lighting and operating machinery is indispensable. Therefore, to use electricity safely, farmers need to strictly adhere to regulations to avoid unnecessary risks.

Usage principles

To use electricity safely in shrimp farming, several regulations must be strictly followed:

Line

Currently, shrimp farmers still use a single-phase power supply. The electrical wires from the low-voltage line to each shrimp pond must be insulated. Before purchasing electrical wires, farmers need to estimate the total power consumption of the pond to choose wires with a higher load capacity, avoiding buying wires with a small capacity which can easily overload and cause short circuits.

The power lines must run on insulators over concrete poles at least 3 meters high. Bamboo or wooden poles should not be used, and power lines must not be run underground in ponds under any circumstances. The power supply should be routed from the pole to the house or shed via a main circuit breaker (AT). Then, depending on the requirements of each pond or shed, smaller circuit breakers (ATs) should be connected. The appropriate wire size should be chosen depending on the load of each specific device and machine. All circuit breakers, once installed, must be kept in a dry shelter or plastic box.

Outdoor electrical wires, after about a year, will have their plastic insulation peeling off, exposing the wires and posing a significant safety hazard upon contact. Therefore, it is necessary to periodically inspect the wiring, detect problems, and replace them promptly.

Use a pump.

The motor should be installed in a fixed location. When installing, the motor's power supply should be cut off, and a separate circuit breaker should be used to proactively disconnect the power supply in case of a malfunction.

Aeration system

In shrimp farming, aeration systems are essential. Commonly used aerators are 2- and 4-impeller aerators, depending on the pond size. General technical specifications: 2-4 impeller aerators: single-phase electric motor, power 550-750 W, voltage 220-240 V, rotational speed 2,500-3,000 rpm.

The water aerator should be placed 3-5 meters from the shore. Regularly lubricate the motor shaft and belt for smooth operation, and check the tension and locking pins. When running the aerator at night or near dawn, turn on the lights because accidents can easily occur in the dark. Do not wade into the pond while the aerator is running. Weekly inspect the fan blades, motor shaft, etc., to promptly detect any signs of cracks, breaks, or electrical leaks. Regularly use a voltage tester to check the machinery and wiring connections to prevent electrical leaks and shocks.

If the water pump or aerator breaks down, the circuit breaker must be switched off, a sign or notice posted, and only then should repairs be carried out. For the first 15 minutes after starting the machine, always monitor it to ensure it is working properly. Once the machine is running smoothly, check it every two hours, and avoid walking barefoot in the pond.

According to Thuysanspot